SCHMC

Estimation of Diastolic Filling Pressure with Cardiac CT in Comparison with Echocardiography Using Tissue Doppler Imaging: Determination of Optimal CT Reconstruction Parameters

Metadata Downloads
Abstract
Objective
To determine the optimal CT image reconstruction parameters for the measurement of early transmitral peak velocity (E), early peak mitral septal tissue velocity (E′), and E / E′.

Materials and Methods
Forty-six patients underwent simultaneous cardiac CT and echocardiography on the same day. Four CT datasets were reconstructed with a slice thickness/interval of 0.9/0.9 mm or 3/3 mm at 10 (10% RR-interval) or 20 (5% RR-interval) RR-intervals. The E was calculated by dividing the peak transmitral flow (mL/s) by the corresponding mitral valve area (cm2). E′ was calculated from the changes in the left ventricular length per cardiac phase. E / E′ was then estimated and compared with that from echocardiography.

Results
For assessment of E / E′, CT and echocardiography were more strongly correlated (p < 0.05) with a slice thickness of 0.9 mm and 5% RR-interval (r = 0.77) than with 3 mm or 10% RR-interval. The diagnostic accuracy of predicting elevated filling pressure (E / E′ ≥ 13, n = 14) was better with a slice thickness of 0.9 mm and 5% RR-interval (87.0%) than with 0.9 mm and 10% RR-interval (71.7%) (p = 0.123) and significantly higher than that with a slice thickness of 3 mm with 5% (67.4%) and 10% RR-interval (63.0%), (p < 0.05), respectively.

Conclusion
Data reconstruction with a slice thickness of 0.9 mm at 5% RR-interval is superior to that with a slice thickness of 3 mm or 10% RR-interval in terms of the correlation of E / E′ between CT and echocardiography. Thin slices and frequent sampling also allow for more accurate prediction of elevated filling pressure.
All Author(s)
J. S. Hwang ; H. Lee ; B. Lee ; S. J. Lee ; S. S. Jou ; H. K. Lim ; J. Suh
Issued Date
2017
Type
Article
Keyword
Cardiac CTEchocardiographyTissue DopplerVentricular functionDiastolic functionLeft ventricle
Publisher
대한영상의학회
The Korean Society of Radiology
ISSN
1229-6929 ; 2005-8330
Citation Title
Korean journal of radiology
Citation Volume
18
Citation Number
4
Citation Start Page
632
Citation End Page
642
Language(ISO)
eng
DOI
10.3348/kjr.2017.18.4.632