SCHMC

담도 스텐트 이탈에 의한 십이지장 천공 환자에서 지혈클립과 Fibrin Glue를 이용한 내시경 치료 1예

Metadata Downloads
Alternative Title
A Primary Repair with Hemoclips and Fibrin Glue Injection in Biliary Stent Induced Duodenal Perforation
Abstract
Duodenal perforations caused by biliary prostheses are uncommon, but they are potentially life threatening and require immediate treatment. Here we describe an unusual case of duodenal perforation induced by a plastic biliary stent. It masqueraded as a case of cholecystitis and combined systemic upset with a localized peritonitis and fever. Primary endoscopic closure by hemoclips was difficult due to the position of the lateral wall and the complexity of aligning the perforation with the endoscope. To approximate the perforated hole and adherent hemoclips, glue injection and sprayings were successfully performed under cap-fitted endoscopy. The patient recovered without additional complications.
All Author(s)
K. W. Kim ; T. H. Lee ; S. H. Park ; B. S. Son ; S. H. Lee ; I. K. Chung ; S. J. Kim
Issued Date
2011
Type
Article
Keyword
Endoscopic retrogradecholangiopancreatography (ERCP)Biliary stentIntestinal perforationHemoclipGlue injection
Publisher
대한소화기내시경학회
The Korean Society of Gastrointestinal Endoscopy
ISSN
1225-7001
Citation Title
대한소화기내시경학회지
Korean Journal of Gastrointestinal Endoscopy
Citation Volume
42
Citation Number
6
Citation Start Page
437
Citation End Page
441