Feasibility and safety of a novel dedicated device for one-step EUS-guided biliary drainage: A randomized trial
- Abstract
- BACKGROUND AND AIMS: EUS-guided biliary drainage (EUS-BD) has been proposed as an alternative for patients after failed ERCP. To date, the evaluation of dedicated device for one-step EUS-BD has been limited. To determine feasibility and safety of a newly designed 7F stent introducer with tapered metal tip as a push-type dilator for one-step metal stent placement without additional fistula dilation in EUS-BD. METHODS: Thirty-two patients with malignant biliary obstruction and failed ERCP were randomly assigned to a dedicated stent introducer with a modified hybrid metal stent (DH group, n = 16) or a conventional 8.5F biliary metal stent introducer with a fully covered metal stent (FC group, n = 16). The technical success, procedural times, clinical success rate, and adverse event rates were evaluated. RESULTS: One-step technical success without additional fistula dilation in the DH was 88% (14/16). Multi-step process in a stent placement was performed in all patients of the FC group. The procedural time in the DH was significantly shorter than the FC (10 vs. 15 min, P = 0.007). No difference in overall technical or clinical success was seen between the groups. The rate of an early adverse event was common in the FC compared with the DH (31.3% [5/16] in the FC vs. 6.3% [1/16] in the DH, P = 0.172), although not statistically significant. CONCLUSIONS: A dedicated device for one-step EUS-BD may be technically feasible, safe, and shorten the procedural times with less chance of an additional fistula dilation process, resulting in a potential reduction of the early adverse events.
- All Author(s)
- D. H. Park
; T. H. Lee
; W. H. Paik
; J. H. Choi
; T. J. Song
; S. S. Lee
; D. W. Seo
; S. K. Lee
; M. H. Kim
- Intsitutional Author(s)
- 이태훈
- Issued Date
- 2015
- Type
- Article
- Keyword
- biliary; neoplasms; endoscopic ultrasound; endoscopy: pancreato-biliary [ERCP]; gastroenterology.
- Publisher
- Asian Pacific Association of Gastroenterology
Asian Pacific Association for the Study of the Liver
- ISSN
- 0815-9319
- Citation Title
- Journal of Gastroenterology and Hepatology
- Citation Volume
- 30
- Citation Number
- 10
- Citation Start Page
- 1461
- Citation End Page
- 1466
- Language(ISO)
- eng
- DOI
- 10.1111/jgh.13027
- URI
- http://schca-ir.schmc.ac.kr/handle/2022.oak/3890