SCHMC

성문암 세기조절 방사선치료에서 변형영상정합을 이용한 선량변화 평가

Metadata Downloads
Alternative Title
Evaluation of Dose Change by Using the Deformable Image Registration (DIR) on the Intensity Modulated Radiation Therapy (IMRT) with Glottis Cancer
Abstract
The purpose of this study is to evaluate the variation of the dose which is delivered to the patients with glottis cancer under IMRT (intensity modulated radiation therapy) by using the 3D registration with CBCT (cone beam CT) images and the DIR (deformable image registration) techniques. The CBCT images which were obtained at a one-week interval were reconstructed by using B-spline algorithm in DIR system, and doses were recalculated based on the newly obtained CBCT images. The dose distributions to the tumor and the critical organs were compared with reference. For the change of volume depending on weight at 3 to 5 weeks, there was increased of 1.38~2.04 kg on average. For the body surface depending on weight, there was decreased of 2.1 mm. The dose with transmitted to the carotid since three weeks was increased compared be more than 8.76% planned, and the thyroid gland was decreased to 26.4%. For the physical evaluation factors of the tumor, PITV, TCI, rDHI, mDHI, and CN were decreased to 4.32%, 5.78%, 44.54%, 12.32%, and 7.11%, respectively. Moreover, $D_{max}$, $D_{mean}$, $V_{67.50}$, and $D_{95}$ for PTV were increased or decreased to 2.99%, 1.52%, 5.78%, and 11.94%, respectively. Although there was no change of volume depending on weight, the change of body types occurred, and IMRT with the narrow composure margin sensitively responded to such a changing. For the glottis IMRT, the patient's weight changes should be observed and recorded to evaluate the actual dose distribution by using the DIR techniques, and more the adaptive treatment planning during the treatment course is needed to deliver the accurate dose to the patients.
All Author(s)
김우철 ; 민철기 ; 이석 ; 최상현 ; 조광환 ; 정재홍 ; 김은석 ; 여승구 ; 권수일 ; 이길동
Issued Date
2014
Type
Article
Keyword
GlotticDeformable image registrationCBCTAdaptive radiation therapy
Publisher
한국의학물리학회
ISSN
1226-5829 ; 2288-9620 ; 2508-4445 ; 2508-4453
Citation Title
Korean Journal of Medical Physics
Citation Volume
25
Citation Number
3
Citation Start Page
167
Citation End Page
175
Language(ISO)
kor
URI
http://schca-ir.schmc.ac.kr/handle/2022.oak/468
Appears in Collections:
방사선종양학과 > 1. Journal Papers
공개 및 라이선스
  • 공개 구분공개
  • 엠바고Forever
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.