성문암 세기조절 방사선치료에서 변형영상정합을 이용한 선량변화 평가
- Alternative Title
- Evaluation of Dose Change by Using the Deformable Image Registration (DIR) on the Intensity Modulated Radiation Therapy (IMRT) with Glottis Cancer
- Abstract
- The purpose of this study is to evaluate the variation of the dose which is delivered to the patients with glottis cancer under IMRT (intensity modulated radiation therapy) by using the 3D registration with CBCT (cone beam CT) images and the DIR (deformable image registration) techniques. The CBCT images which were obtained at a one-week interval were reconstructed by using B-spline algorithm in DIR system, and doses were recalculated based on the newly obtained CBCT images. The dose distributions to the tumor and the critical organs were compared with reference. For the change of volume depending on weight at 3 to 5 weeks, there was increased of 1.38~2.04 kg on average. For the body surface depending on weight, there was decreased of 2.1 mm. The dose with transmitted to the carotid since three weeks was increased compared be more than 8.76% planned, and the thyroid gland was decreased to 26.4%. For the physical evaluation factors of the tumor, PITV, TCI, rDHI, mDHI, and CN were decreased to 4.32%, 5.78%, 44.54%, 12.32%, and 7.11%, respectively. Moreover, $D_{max}$, $D_{mean}$, $V_{67.50}$, and $D_{95}$ for PTV were increased or decreased to 2.99%, 1.52%, 5.78%, and 11.94%, respectively. Although there was no change of volume depending on weight, the change of body types occurred, and IMRT with the narrow composure margin sensitively responded to such a changing. For the glottis IMRT, the patient's weight changes should be observed and recorded to evaluate the actual dose distribution by using the DIR techniques, and more the adaptive treatment planning during the treatment course is needed to deliver the accurate dose to the patients.
- All Author(s)
- 김우철
; 민철기
; 이석
; 최상현
; 조광환
; 정재홍
; 김은석
; 여승구
; 권수일
; 이길동
- Issued Date
- 2014
- Type
- Article
- Keyword
- Glottic; Deformable image registration; CBCT; Adaptive radiation therapy
- Publisher
- 한국의학물리학회
- ISSN
- 1226-5829
; 2288-9620
; 2508-4445
; 2508-4453
- Citation Title
- Korean Journal of Medical Physics
- Citation Volume
- 25
- Citation Number
- 3
- Citation Start Page
- 167
- Citation End Page
- 175
- Language(ISO)
- kor
- URI
- http://schca-ir.schmc.ac.kr/handle/2022.oak/468
- 공개 및 라이선스
-