SCHMC

급성 발작으로 내원한 성인 천식 환자에서 Nebulized Budesonide의 임상적인 효과와 시상하부-뇌하수체-부신 축에 대한 작용

Metadata Downloads
Alternative Title
Clinical Validation of Nebulized Budesonide and Effect of Nebulized Budesonide on the Hypothalamic-Pituitary-Adrenal Axis in Adult Patients Admitted with Acute Asthmatic Attack
Abstract
Background : Many clinicians are reluctant to prescribe systemic corticosteroids to manage an asthmatic attack because of many complications such as osteoporosis, cushing's syndrome, diabetes, hypertension and bleeding tendency. The use of nebulized budesonide may be of value in some infants, old men, and in particular adult asthmatic patients who complain of severe dyspnea. A clinical validation and steroid-sparing effect of nebulized budesonide in asthmatic adults and COPD were evaluated, and the short-term effects of budesonide use on the HPA axis were assessed. Materials and Methods : Study A was prospectively done with 41 patients diagnosed with pure asthma and 30 patients diagnosed with COPD (including asthmatic component) in Soonchunhyang Hospital, Chunan from June. 2000 to Sep. 2001. They were treated with nebulized budesonide including systemic steroids (Group 1), a budesonide tubuhaler including a systemic steroid (Group 2), or only the systemic steroid(Group 3). The peak flow rate, arterial blood gas in room air, pulmonary function test, symptom scoring, steroid amount and hospital stay were analyzed. Study B was conducted with 19 patients to evaluate the short-term effects on the HPA axis of treatment with nebulized budesonide 1mg twice daily and a budesonide turbuhaler 5 puffs twice daily. The adrenal function was assessed prior to budesonide inhalation and after 7 days of budesonide inhalation. Results : In the pure asthmatic patients, the mean value of the symptoms (dyspnea, wheezing, cough, night asthma) or the arterial BGAs, total amounts of steroid or hospital stay and the difference in the results of the pulmonary function tests or peak expiratory flow rate were similar in the three groups. In COPD with an asthmatic component, there were no significant differences among the three groups. Although nebulized budesonide suppressed HPA function,(p=0.006) the HPA responses from the nebulized budesonide and turbuhaler budesonide were similar (p=0.288) Conclusion : This result suggests that systemic steroid should only be made available for acute asthmatic patients irrespective of the inhaled budesonides. Nebulized budesonide at the therapeutic dose has similar effects on the HPA axis compared to that of turbuhaler budesonide.
All Author(s)
서기현 ; 문승혁 ; 김용훈
Issued Date
2002
Type
Article
Keyword
Nebulized budesonideBAHPA (hypothalamic-pituitary-adrenal) axis
Publisher
대한결핵및호흡기학회
ISSN
0378-0066 ; 1738-3536 ; 2005-6184
Citation Title
결핵 및 호흡기질환
Tuberculosis and Respiratory Disease
Citation Volume
52
Citation Number
5
Citation Start Page
529
Citation End Page
538
Language(ISO)
kor
DOI
10.4046/trd.2002.52.5.529
URI
http://schca-ir.schmc.ac.kr/handle/2022.oak/661
Appears in Collections:
호흡기내과 > 1. Journal Papers
공개 및 라이선스
  • 공개 구분공개
  • 엠바고Forever
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.